华流仪表

Nozzle Flowmeter

Nozzle Flowmeter
Differential Pressure Flowmeters

Nozzle Flowmeter

Standard nozzle primary element; erosion-resistant and suited to high-temperature, high-pressure, high-velocity steam.

Nominal diameter (DN)
DN50~630mm (DN>500 can also be designed and manufactured)
Accuracy class
Standard nozzle ±1.0%; long-radius nozzle ±2.0%
Applicable media
Especially suitable for high-temperature, high-pressure steam and water; also applicable to various gases and liquids
Features
  • Erosion-resistant, long service life
  • Suitable for high temperature, high pressure and high velocity
ISO triple-system Ex-proof SIL2 CE Pattern approval

Overview

The HUALIU Nozzle Flowmeter is a differential-pressure flow measurement device that, combined with various differential-pressure gauges or transmitters, measures the flow of liquids, steam, gases and other fluids in pipelines. It is widely used in the petroleum, chemical, metallurgical, power and light industries. The product is available in two primary-element forms, the standard nozzle (ISA1932 nozzle) and the long-radius nozzle, both designed and manufactured in accordance with ISO5167 and GB/T2624. Owing to their high degree of standardization, they can generally be put into service without flow calibration.

Its measuring principle is that when fluid flows through the nozzle primary element a static differential pressure is created; a definite correlation exists between this differential pressure and the flow rate, from which the flow is derived. The nozzle uses an arc-shaped converging profile, giving a stable discharge coefficient and good repeatability, and can measure a wide range of liquids, gases, steam and dusty or dirty media. Compared with an orifice plate flowmeter, the nozzle has a lower permanent pressure loss, helping to save energy.

The HUALIU Nozzle Flowmeter is simple in structure and easy to install, requiring a short upstream straight run. Fully forged, the body is robust, durable, erosion-resistant and corrosion-resistant, withstanding high-temperature, high-pressure and high-velocity conditions. It is particularly suited to the flow measurement of superheated steam and high-temperature, high-pressure water in the power, chemical and related industries.

Specifications

Nominal diameter (DN)DN50~630mm (DN>500 can also be designed and manufactured)
Accuracy classStandard nozzle ±1.0%; long-radius nozzle ±2.0%
Applicable mediaEspecially suitable for high-temperature, high-pressure steam and water; also applicable to various gases and liquids
Pressure rating≤42MPa
Medium temperature-50℃~650℃
Primary element typeStandard nozzle (ISA1932 nozzle), long-radius nozzle
Pressure tapping methodCorner taps for standard nozzle; D and D/2 (D-D/2) taps for long-radius nozzle
StandardsISO5167, GB/T2624
Body materialFlange or clamping element in carbon steel, alloy steel or stainless steel per medium temperature; nozzle in stainless steel 304 or 316
Connection typeFlange-clamped, fastener-clamped, welded
Structure typeIntegral, remote, welded, dual-flange
Compensation methodNo compensation, single pressure compensation, single temperature compensation, pressure and temperature compensation

Applications

High-pressure steam
Power plant main steam metering

Request a Quote